Zinc Flake for High-Strength Fasteners
Zinc flake coating protects high-strength fasteners with no hydrogen embrittlement risk
Zinc flake coating is a mechanically applied zinc-aluminium flake coating used on bolts, studs and structural fasteners that cannot carry the hydrogen embrittlement risk of an electroplated coating. The coating is applied as a flake dispersion and cured to form a protective matrix, so no hydrogen is generated during the process and the fastener's mechanical properties are not put at risk.
For a buyer, specifying zinc flake means fixing four things on the drawing: the fastener class and material, the coating system and chemistry, the build and cure, and the test standard and evidence you expect with the delivery.
Fukar applies zinc flake coating from its Shah Alam facility under ISO 9001:2015 quality management, and corrosion performance is verified by per-batch ASTM B117 testing with a salt spray test report issued against the specification ordered.
Comparison
Zinc Flake Coating Against Zinc Plating and Zinc Nickel
All three coatings protect steel fasteners, but they get there by different routes and carry different risks. The table below compares the three coatings Fukar applies to fasteners.
Discuss Your Spec| Attribute | Zinc Flake Coating | Zinc Plating (ASTM B633) | Zinc Nickel Plating (ASTM B841) |
|---|---|---|---|
| Application method | Mechanically applied zinc-aluminium flake | Electrodeposited in a zinc bath | Electrodeposited in a zinc-nickel alloy bath |
| Hydrogen embrittlement risk | None — the process does not induce hydrogen embrittlement | Present on acid-plated finishes; bake embrittlement relief is mandatory for steel at or above 1,000 MPa | Present; bake embrittlement relief is required, and every zinc nickel job on hardened steel is baked as standard |
| Post-treatment | Cured flake matrix, with any topcoat stated separately | Chromate passivation: blue, yellow or black | Trivalent chromate or a topcoat, as specified |
| Corrosion evidence | Per-batch ASTM B117 salt spray test report | Per-batch ASTM B117 salt spray test report | Per-batch ASTM B117 salt spray test report |
| Coating class reference | Zinc-aluminium flake systems, project-specific requirements | ASTM B633 | ASTM B841 |
| Typical use | High-strength bolts, structural fasteners, anchors and oil and gas bolting systems | Fasteners, brackets, anchors and general industrial hardware | Brake components, underbody fasteners, fuel system hardware and severe-duty industrial fasteners |
Why Engineers Specify It
Why Zinc Flake Is Chosen for Fasteners
No hydrogen embrittlement
The coating is applied mechanically, so no hydrogen is generated and the fastener keeps its mechanical properties. That is the reason zinc flake is specified in preference to electroplating on the highest-strength bolt classes.
Corrosion protection for severe service
Zinc flake is used where standard coatings do not meet the corrosion life target: oil and gas bolting systems, structural fasteners and exposed construction hardware.
Controlled build and cure
Application and curing parameters are controlled under ISO 9001:2015 quality management, and the finished coating is checked against the approved sample before the batch is released.
Drawing Notes
What to Put on the Drawing for Zinc Flake Coated Fasteners
A zinc flake instruction is only complete when it names the fastener class, the coating system, the build and the test standard. Anything left open at RFQ stage is where programs go wrong.
Discuss Your Spec| Drawing note | What it settles |
|---|---|
| Fastener class and material | Sets the process route. Zinc flake is selected precisely because the fastener is high-strength and cannot tolerate hydrogen embrittlement. |
| Coating system and chemistry | Identifies the flake system to be applied, so the supplier quotes the same system that will be delivered. |
| Coating build | States the thickness to be achieved, and the points on the part where it is measured. |
| Topcoat, where required | Separates the base coating from any additional topcoat, so the inspection points are unambiguous. |
| Test standard and evidence | Names ASTM B117 and the corrosion target in hours to white / red rust, so the per-batch report is issued against the specification ordered. |
| Acceptance appearance | Confirms what a good part looks like, so a reject is judged against an agreed sample rather than an opinion. |
How It Works
The Zinc Flake Coating Process Flow
1. Degrease & Clean
Alkaline and emulsion degreasing removes cutting oils, drawing lubricants and shop soils, with rinsing between stages so no organic carry-over reaches the coating line.
2. Surface Preparation
The surface is prepared to a clean profile with oxide and loose material removed, so the flake layer bonds to the substrate rather than lifting away from it.
3. Zinc Flake Application
The zinc-aluminium flake system is applied in a controlled operation, building the coating to the thickness called out on the drawing.
4. Thermal Curing
Coated parts are oven-cured so the flake matrix forms and hardens into a single protective layer.
5. Topcoat, Where Specified
Where the drawing calls for an additional topcoat, it is applied over the cured base coat as a separate controlled step.
6. Inspect & Certify
Coating thickness and appearance are checked against the approved sample, and a certificate of conformance is issued for the batch.
Test Evidence
What to Ask About the Test Evidence
Corrosion performance for zinc flake is verified by per-batch ASTM B117 testing, with a salt spray test report issued against the specification ordered. Ask for the report to be issued against your own drawing, not against a general specification.
Ask what else travels with the delivery: the certificate of conformance recording the process and the coating system, and the record of the batch it was applied to. Both are useful when a batch is queried later.
Before You Order
Zinc Flake Coating Specification Checklist
Six things to confirm on the drawing or RFQ, so the job is quoted and run without a clarification loop.
Material and strength
- Zinc flake is chosen for high-strength fasteners. Confirm the fastener class, material and tensile strength on the drawing.
- Because the coating is applied mechanically, no hydrogen is generated during the process, so the embrittlement risk that drives this choice is not created.
- Confirm whether the fastener is new, reconditioned or reused, and state the condition of the surface before coating.
Grade and thickness
- State the coating system and chemistry to be applied, and the build to be achieved.
- Give the coating thickness per surface with its tolerance, and say where it is measured on the part.
- Name the topcoat separately if one is required, so the inspection points are unambiguous.
Common defects to watch
- Flake build that is thin or patchy on threads and recesses points to incomplete preparation before application.
- Lifting or flaking of the cured layer usually traces back to contamination or an oxide layer left on the surface.
- Runs and uneven coverage on threads and recesses are worth flagging before the batch is scheduled rather than after.
Inspection and evidence
- Ask for the per-batch ASTM B117 salt spray test report against the specification ordered, and the certificate of conformance recording the process.
- Coating thickness is verified on each batch at the points your drawing calls out.
- State the acceptance appearance reference, so a reject is judged against an agreed sample.
Common Questions
Zinc Flake Coating for Fasteners FAQ
Answers to the specification and process questions engineering and procurement teams ask most often.
Ask a Technical QuestionWhat is zinc flake coating used for on fasteners?
Zinc flake coating is used on high-strength fasteners, structural hardware, anchors and oil and gas bolting systems that need corrosion protection but cannot carry the hydrogen embrittlement risk of an electroplated coating.
Why is zinc flake coating used instead of zinc plating on high-strength bolts?
Zinc flake coating is applied mechanically, so no hydrogen is generated and the fastener's mechanical properties are not put at risk. Electroplated zinc and zinc nickel coatings carry that risk, and on steel at or above 1,000 MPa bake embrittlement relief becomes mandatory or is run as standard.
How is zinc flake coating corrosion performance verified?
Corrosion performance for zinc flake is verified by per-batch ASTM B117 testing. Fukar issues a salt spray test report per batch against the specification ordered, so the result is tied to your own coating system rather than to a generic figure.
Is zinc flake coating better than zinc plating for fasteners?
It depends on the constraint. Zinc flake is the right answer when the fastener is high-strength and hydrogen embrittlement risk is not acceptable, or when the service environment is severe. Zinc plating to ASTM B633 remains the economical choice for general hardware, brackets and anchors in moderate environments.
What should be specified on a drawing for zinc flake coated fasteners?
State the fastener class and material, the coating system and chemistry, the coating build with its tolerance and measurement points, any topcoat, the test standard with the corrosion target in hours to white / red rust, and the acceptance appearance. Send those six points and the job can be quoted and run without a clarification loop.
Related Pages
Coating Services Hub
Explore zinc flake, fluoropolymer and Xylan systems with coating selection guidance.
View hub →Zinc Flake Coating
See the zinc flake service, its specification snapshot and coating selection guidance.
View service →Oil & Gas Industry
See coating requirements for oil and gas bolting systems and severe-service fastener applications.
View industry →Need zinc flake coating support for your high-strength fasteners?
Share your fastener class, coating system and corrosion target. We'll review the requirement and confirm the coating route before production.